4006 737 110China WandaEN

HOMEPRODUCTS > Logging Cable >

MONOCONDUCTOR 7/32'' VS 5/16'' 

  • PROPERITIES

    Cable Diameter        7/32''(5.6mm)          5/16(8.0mm)
    Minimum Sheave Diameter   11''(280mm)           16''(400mm)
    Cable Stretcch Coefficient    2.2 ft/Kft/Klbs(2.5m/Km/5KN)   1.2ft/Kft/Klbs(1.35m/Km/5KN)
  • ELECTRICAL

    Maximum Conductor Voltage     1,000VAC              1,000VAC
    Conductor AWG Rating         16                14
    Minimum Insulation Resistance     1,640MΩ/Kft(500MΩ/Km)     1,640MΩ/Kft(500MΩ/Km)
  • MECHANICAL

    Cable Breaking Strength
    Ends Fixed                 6,300 lbs(28KN)     12,375 lbs(55KN)
    MAximum Suggested Working Tension      4,725 lbs(21KN)     9,281 lbs(55KN)
    Number and Size Wires
    Inner Armor                 15 wires  0.61mm     12 wires 1.11mm
    Outer Armor                 15 wires  0.89mm     18 wires  1.11mm


Cable Type

Main Description

Cable Weight

Temp Rating

Insulation Type

Insulation Thickness

Copper Construction

Resistance

Cap.Typical

O.D Inmm

Lbs/Kft/Kg/Km

W1F-5.6 HS 1*1.35

450℉
232℃

FEP

0.021in
0.55mm

19*0.30mm

4.0Ω/Kft
13.1Ω/Km

58pF/ft
190pF/m

0.22
5.6

92
137

W1F-8.0 HS 1*2.0

450℉
232℃

FEP

0.033in
0.85mm

19*0.37mm

2.80Ω/Kft
9.2Ω/Km

58pF/ft
190pF/m

0.32
8.0

184
274


Copyright:China Wanda Group   
Support:www.546dns.cn   
sitemap